Frequency range : 75 MHz to 170 MHz (5 standard frequencies : 76.8 MHz, 100 MHz, 125 MHz, 150 MHz, 156.25 MHz)
Supply voltage : 1.62 V to 3.63 V
Function : Output enable(OE/OE) or Standby(ST/ST)
Frequency tolerance, operating temperature
±15 × 10-6 (-40℃ to +105℃)
±20 × 10-6 (-40℃ to +105℃) *Includes 10 years aging
±25 × 10-6 (-40℃ to +125℃)
±30 × 10-6 (-40℃ to +125℃) *Includes 10 years aging
±50 × 10-6 (-40℃ to +125℃)
±55 × 10-6 (-40℃ to +125℃) *Includes 10 years aging